GAS
Coriolis
Orifice
Turbine
USM
Gas flow meters for custody transfer and process applications
The FLOWSIC600 measurement device is an ultrasonic gas flow meter and sets the standard in its market segment for custody transfer of natural gas as well as steam flow measurement. The visually technical design demonstrates that it is geared to the tough industry conditions. The compact design with integrated cable routing means that the measuring system is rugged, insensitive to interference, low-maintenance, and has long-term stability. The FLOWSIC600 features extensive diagnostics options to allow detection of malfunctions even before the measurement is affected. Versions with 2, 4, 4 + 1, or 4 + 4 measuring paths enable a variety of process applications, including custody transfer measurements.
- At a glance
- Highly efficient ultrasonic transducer - up to gas temperatures of 280 °C and pressures up to 450 bar
- Direct path layout
- Intelligent self-diagnostics
- Compact, robust design
- Integrated log book and data logger
- Large measuring range 1:120
- Bidirectional measurement
- Low power consumption: <1 W
APPLICATIONS
- Fields of applications
- Custody transfer applications (natural gas, N2, O2, air, ethylene)
- Onshore and offshore applications
- Steam flow measurement
- Underground gas storage facilities (bidirectional measurement possible)
- Cryogenic gas applications down to –194 °C
- Also for process gases
- For gas with high H2S component such as sour gas or biogas
Technical data overview
Measured values | Volumetric flow, a. c., volume a. c., gas velocity, sound velocity | |||||||||||||||||||||||
Number of measuring paths | 2, 4, 4+1, 4+4 | |||||||||||||||||||||||
Hazardous area | 1G | |||||||||||||||||||||||
2G | ||||||||||||||||||||||||
Class I Division 1 | ||||||||||||||||||||||||
Class I Division 2 | ||||||||||||||||||||||||
Measuring ranges | Measuring ranges depend on nominal pipe size | |||||||||||||||||||||||
Gas temperature | –40 °C … +180 °C | |||||||||||||||||||||||
On request: –194 °C … +280 °C | ||||||||||||||||||||||||
Operating pressure | 0 bar (g) … 250 bar (g) | |||||||||||||||||||||||
On request: 450 bar (g) | ||||||||||||||||||||||||
Nominal pipe size | 2 ″ … 48 ″ | |||||||||||||||||||||||
(DN 50 … DN 1200) | ||||||||||||||||||||||||
Conformities | AGA-Report No. 9 | |||||||||||||||||||||||
API 21.1 | ||||||||||||||||||||||||
OIML D 11:2013 | ||||||||||||||||||||||||
OIML R 137-1:2006 | ||||||||||||||||||||||||
ISO 17089-1 | ||||||||||||||||||||||||
BS 7965 | ||||||||||||||||||||||||
Enclosure rating | IP65 / IP66 / IP67 | |||||||||||||||||||||||
Modbus | ✔ | |||||||||||||||||||||||
Type of fieldbus integration | ASCII RS-485 (2x) | |||||||||||||||||||||||
RTU RS-485 (2x) | ||||||||||||||||||||||||
HART | ✔ | |||||||||||||||||||||||
Diagnostics functions | Integrated device diagnosis and extended diagnosis via MEPAFLOW600 CBM software |